chamber pressure is greater than the lower chamber, the valve closed, stop water supply. When the level fell by more than a preset position, the float pilot valve opens, the chamber pressure is less than the inferior vena cava pressure the valve opens the valve to the pool water. Angle type water level valve, constant water level valve angle constant water level valve installation is convenient, can save pipe elbow, save installation space. The valve maintenance is simple, flexible and durable, high accuracy of level control, the water level is not affected by water pressure interference and close watertight, reliable performance, low cost. The floating ball can be installed with the height and distance of the pool.
Note: parameters are for reference only, or are not full. Valve can be used in accordance with the requirements of different pressure, material, diameter, drive, etc.. Specific please contact or online advisory contact.
When the pool or tank water level float valve, open the drain pipe, water pressure valve piston will hold up in the water, the sealing surface of open water supply valve is open. When the water level rises to the control line, the float valve is closed. The piston moves down to catch the sealing surface and stop the water supply from the closed door.